MATERIAL SAFETY DATA SHEET MUSSON NO. 300 STAIR TREAD AHDESIVE |
||
NPCA HMIS H=1 |
Prepared by: Tim Brown Date: June 7, 2006 |
|
SECTION I |
||
| Manufactured For: The R.C. Musson Rubber Company | ||
| Street Address: 1320 E Archwood Ave, Akron, Ohio 44306 | ||
| Emergency Telephone No.: Chemtrec 1-800-424-9300 | ||
| General Information No.: 1-800-228-4583 | ||
| Product Class: Floor Covering Adhesive | ||
| Manufacturer’s Code Identification: Musson 300 | ||
| Trade Name: Stair Tread Adhesive |
SECTION II – HAZARDOUS INGREDIENTS |
| None |
SECTION III – PHYSICAL DATA |
| Boiling Range: Greater than 212°F |
| Vapor Density: Lighter than air |
| Evaporation Rate: Slower than Ether |
| Percent Volatile by Volume: 29.5 ± .5% |
| VOC Emission: 0 g/l (calculated per Ca. South Coat Rule 1168) |
SECTION IV – PHYSICAL DATA |
||
| DOT Category: Nonflamable | ||
| Flash Point: N/A | ||
| LEL: Not Known | ||
| Extinguishing Media: Water mist, dry chemical, CO2, mechanical foam | ||
Unusual Fire Fighting Hazards: Liquid adhesive will not ignite. Dried adhesive will ignite if heated over 150ºC and/or exposed to ignition source, producing CO, CO2, smoke and hydrocarbons. |
||
Special Fire Fighting Procedures: If dried adhesive ignites, use dry chemical, foam extinguishers, or a fog nozzle. For small fires, CO2 extinguishers can be used. Use air mask when combating dried adhesive fires. |
||
SECTION V – HEALTH HAZARD DATA |
| Threshold Limit Value: Non-established |
| Effects of overexposure: Wet-possible lightheadedness, nausea, and/or mild dermatitis could develop. Dry-none |
| Emergency & First Aid Procedures: Flush eyes with ample water. Wash skin with soap and water. If ingested, treat symptomatically and contact physician. |
SECTION VI – REACTIVITY DATA |
| Stability: Stable |
| Incompatibility: (Materials to avoid) |
| Conditions to avoid: Closed area with open container |
| Hazardous Decomposition Products: None |
| Hazardous Polymerization: Will not occur |
| Conditions to avoid: Strong acids or oxidants, temperatures below 20ºF |
SECTION VII – SPILL OR LEAK PROCEDURES |
| Steps to be taken in case material is released or spilled: Scoop up excess with shovel, wash remainder with water. |
| Waste Disposal Method: Landfill or incinerate as per local and state regulations. |
SECTION VIII – SPECIAL PORTECTION INFORMATION |
| Respiratory Protection: None required with adequate ventilation. |
| Ventilation: Open windows, exhaust fan, open air area |
| Protective Gloves: May be desirable for people with sensitive skin. |
| Eye Protection: Safety gloves or goggles. |
| Other Protective Equipment: None required |
SECTION IX – SPECIAL PRECAUTIONS |
| Precautions to be taken in handling and storing: Store in a cool, dry place. Optimum storage temperature 70ºF. |
| Other precautions: Keep from freezing. Keep sealed when not in use. If frozen, allow adhesive to thaw at room temperature. DO NOT agitate or stir until adhesive is completely thawed. |
| Shelf Life: One year from the date of manufactured in an unopened container |